Convert a DeST model to EnergyPlus model
to_idf.RdConvert a DeST model to EnergyPlus model
Arguments
- dest
A [string or DBIConnection] path to a DeST model file or a DBIConnection object.
- ver
[string] A character string specifying the EnergyPlus version. It can be
"latest", which is the default, to indicate using the latest EnergyPlus version supported by the {eplusr} package. Objects are generated using the project's EnergyPlus 9.0.1 baseline. Earlier targets are not maintained. Effective moisture raises the generation baseline to 9.1. Effective detailed N2 source angle tables require 9.2. Targets must support all effective features. Higher targets are produced witheplusr::transition(), not separate object writers. Physical HVAC requires the generation version's local ExpandObjects; target and intermediate IDDs are resolved by eplusr for transition. The generation/target versions are recorded in the conversion audit. Geometry compatibility has been validated against EnergyPlus 23.1; other versions currently reuse that profile with an explicit warning.- copy
[logical] Whether to copy the input DeST database to a temporary SQLite database. Note that if
FALSE, the input database will be modified during the conversion. Default isTRUE.- verbose
[logical] Whether to show verbose messages. Default is
FALSE.- options
[string or destep_options] Conversion configuration. Use
"objects"(default) ordestep_opts()to configure source inputs, time tables and HVAC representation.
Value
[eplusr::Idf] The converted EnergyPlus model. The
conversion attribute and Version comments record the selected
options, resolved HVAC representation, source component record counts,
and necessary EMS programs.
Its window_bindings table records the window, side, source surface,
host enclosure/surface and original/restored ownership and type for
each restored face. Restoration is also recorded in saved IDF comments.
Its windows table records the
type K/SC, row K, effective glass resistance, face blackness, chosen
target representation and unresolved properties for each window.
Supported positive-type two-layer windows use equivalent ordinary
glazing with SC-derived source angle solar/grey-visible tables and ordered
emissivities. Visible reflectance uses the recovered optical stack as
a grey symmetric equivalent. Saved visible fields are audit metadata
on this verified source branch; they do not control qualification.
Other windows retain the nominal SimpleGlazing approximation. Angular
interpolation and target diffuse integration remain approximations;
native absorption node placement and glass heat capacity are not
reproduced. Conversion does not run an optical preparation simulation.
Its solar list records saved mode bindings/weights, unresolved
references and raw receiver metadata. Saved source surface-family
weights are audit information, not applied target distributions.
EnergyPlus retains its own indoor solar and radiant-gain allocation.
These assumptions also appear in saved IDF comments and do not
establish whole-building equivalence.
Its simulation$response records the actual target zone timestep and
the verified native hourly-response/reporting boundary. Native hourly
control loads and target system-step or averaged hourly loads need not
share their peak value or hour. These notes do not alter target solver
settings, shift the time axis or fit output loads.
Details
Outdoor ventilation retains the source minimum ACH time table.
A saved OPTION.VARIANT_VENT = 0 disables the range supplement.
When the saved switch is absent, conversion retains its legacy
documented outdoor-temperature-band rule and warns about the assumed
enabled setting. The ventilation attribute records this selection.
A room group with IS_AC_ROOM = 0 retains minimum ventilation only;
unused maximum and temperature-range references are not consumed.
In the default outdoor-band rule, the AC availability time table does
not gate the range increment. Explicit target prediction uses that
schedule in its own-state selection and supports intermediate flow.
The rule preserves the remaining range inputs
but does not reproduce DeST's internal ventilation control algorithm.
See destep_opts() for standalone target-state controls, their version
requirements and approximations; none consumes source simulation results.
Window-side surfaces stored with OF_ROOM = -1 are restored from the
same side of their explicit WINDOW.OF_ENCLOSURE host. Restoration
requires unique references, an existing room/outdoor/ground owner and
no conflicting binding on the other side. Ambiguous or incomplete
relationships stop conversion. Only OF_ROOM and TYPE are restored;
geometry and thermal properties are retained. The default copy = TRUE
leaves the input database unchanged. A
destep_restored_window_bindings warning carries the affected records
in its bindings field. This restores redundant input relationships,
not missing geometry or DeST solver behavior.
Storey multipliers are mapped to ZoneGroup independently of source
surface boundaries. Outdoor, ground and interzone relationships are
retained. Interzone pairs with unequal multipliers produce a warning
and are listed in conversion$surface_boundaries: weighted outputs
must not be interpreted as a physically balanced whole-building model.
Successful conversion does not establish DeST thermal equivalence.
Missing enclosure-side or middle-plane references produce a
destep_invalid_surface_references error whose references table identifies
the source enclosure, field and saved reference.
Conversion scope
Source inputs are mapped to EnergyPlus objects with documented equivalent
representations where needed. Conversion does not reproduce DeST solver
algorithms or guarantee matching annual loads. Unsupported selected HVAC
equipment stops automatic/physical conversion with a diagnostic; it is not
replaced silently by IdealLoads. See destep_opts() for supported subsets.
Internal gains retain the source air and total radiant fractions. Separate
surrounding-surface, floor and roof fractions are not mapped to EnergyPlus;
effective sensible sources using these fractions produce a
destep_unsupported_gain_distribution warning. The warning's distributions
field records the affected gain types and source modes. Receiving-surface
allocation and the resulting transient loads are not guaranteed equivalent.
Heating setpoints above cooling setpoints are diagnosed only during hours
when the effective room-type AC availability schedule is greater than zero.
A destep_thermostat_conflict warning identifies the heating, cooling and
availability schedule IDs, rooms and conflicting hours. The same table is
retained in conversion$schedules$temperature_conflicts. Original schedules
are preserved, including inactive inverted values; this diagnostic does not
guarantee that EnergyPlus accepts the controls during a simulation.
Terrain, solar distribution and shading-update settings retain EnergyPlus
defaults. Edit the returned eplusr::Idf to change target simulation settings.
See also
to_epw(), destep_opts() for supported inputs and HVAC limitations.
Examples
if (FALSE) { # \dontrun{
to_idf(dest, "23.1", options = "objects")
opts <- destep_opts("objects", run_period = c(1L, 31L))
to_idf(dest, "23.1", options = opts)
} # }